Life Science / Bio AFM Probes
-
HQ:NSC14/Cr-Au BS
Gold Coated Soft Tapping Mode AFM Probe- 160 kHz 5.0 N/m
-
-
-
-
HQ:NSC18/Cr-Au BS
Gold Coated Soft Tapping Mode AFM Probe- 75 kHz 2.8 N/m
-
-
-
-
XNC12/Cr-Au BS
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers- 17/67 kHz 0.08/0.32 N/m
-
-
-
HQ:NSC35/Cr-Au BS
AFM Probe with 3 Different Gold Coated Soft Tapping Mode AFM Cantilevers- 205/300/150 kHz 8.9/16/5.4 N/m
-
-
-
-
HQ:NSC36/Cr-Au BS
AFM Probe with 3 Different Gold Coated Soft Tapping Mode AFM Cantilevers- 90/130/65 kHz 1.0/2.0/0.6 N/m
-
-
-
-
HQ:NSC15/Cr-Au BS
Gold Coated Tapping Mode AFM Probe- 325 kHz 40 N/m
-
-
-
-
HQ:CSC17/Cr-Au BS
Gold Coated Contact Mode AFM Probe- 13 kHz 0.18 N/m
-
-
-
-
HQ:NSC18/Cr-Au
Gold Coated Soft Tapping Mode AFM Probe- 75 kHz 2.8 N/m
-
-
-
-
HQ:NSC35/Cr-Au
AFM Probe with 3 Different Gold Coated Soft Tapping Mode AFM Cantilevers- 205/300/150 kHz 8.9/16/5.4 N/m
-
-
-
-
HQ:NSC36/Cr-Au
AFM Probe with 3 Different Gold Coated Soft Tapping Mode AFM Cantilevers- 90/130/65 kHz 1.0/2.0/0.6 N/m
-
-
-
-
XNC12/Cr-Au
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers- 17/67 kHz 0.08/0.32 N/m
-
-
-
HQ:CSC17/Cr-Au
Gold Coated Contact Mode AFM Probe- 13 kHz 0.18 N/m
-
-
-
-
HQ:CSC37/Cr-Au
AFM Probe with 3 Different Gold Coated Contact Mode AFM Cantilevers- 40/20/30 kHz 0.8/0.3/0.4 N/m
-
-
-
-
HQ:NSC14/Cr-Au
Gold Coated Soft Tapping Mode AFM Probe- 160 kHz 5.0 N/m
-
-
-
-
HQ:NSC15/Cr-Au
Gold Coated Tapping Mode AFM Probe- 325 kHz 40 N/m
-
-
-
-
HQ:CSC38/Cr-Au
AFM Probe with 3 Different Gold Coated Contact Mode AFM Cantilevers- 20/10/14 kHz 0.09/0.03/0.05 N/m
-
-
-
-
Videos
-
Uncoated silicon HQ AFM tip close-up
Cr-Au coated silicon HQ AFM tip close-up
Typical radius of uncoated AFM tip
8nm
Resulting AFM tip radius with the coating
<35nm
Full AFM tip cone angle
40°
Total AFM tip height
12-18µm
AFM probe material
n-type silicon
AFM tip coating
Uncoated or gold
Detector coating
GoldGold is chemically inert and hydrophobic, which makes gold coated AFM probes suitable for many experiments in biology and chemistry. Gold coated AFM probes are also used in certain electrical applications.
The coating is deposited on the back side of the AFM cantilever only (Cr-Au models) or on both sides of the AFM cantilever (Cr-Au BS models). The Cr-Au coating is formed as a 30nm Au film with a 20nm Cr sublayer, which is deposited for better adhesion of Au. The coating may cause AFM cantilever bending <3°.
The HQ:NSC and HQ:CSC AFM tips have trihedral shape with a full cone angle of 40° and even smaller at the last 200nm of the AFM tip apex.
1 AFM Cantilever Series
AFM Cantilever Resonance Frequency, kHz Force Constant, N/m min typical max min typical max 14 series 110 160 220 1.8 5.0 13 15 series 265 325 410 20 40 80 16 series 170 190 210 30 45 70 17 series 10 13 17 0.06 0.18 0.40 18 series 60 75 90 1.2 2.8 5.5 19 series 25 65 120 0.05 0.5 2.3 3 AFM Cantilevers Series
AFM Cantilever Resonance Frequency, kHz Force Constant, N/m min typical max min typical max 35 series Cantilever A 130 205 290 2.7 8.9 24 Cantilever B 185 300 430 4.8 16 44 Cantilever C 95 150 205 1.7 5.4 14 36 series Cantilever A 30 90 160 0.1 1.0 4.6 Cantilever B 45 130 240 0.2 2 9 Cantilever C 25 65 115 0.06 0.6 2.7 37 series Cantilever A 30 40 55 0.3 0.8 2 Cantilever B 15 20 30 0.1 0.3 0.6 Cantilever C 20 30 40 0.1 0.4 1 38 series Cantilever A 8 20 32 0.01 0.09 0.36 Cantilever B 5 10 17 0.003 0.03 0.13 Cantilever C 6 14 23 0.005 0.05 0.21